It depends on whether the loft is lived in. We found no public body guidance on what should follow removal, as of 10 November 2026. Where the loft is not lived in, RICS (March 2023) prefers insulation at ceiling level.[1] The Energy Saving Trust (page last updated 15 October 2025) recommends at least 270 mm of loft insulation.[2]
Your next step:Foam removed and foil fitted? Get both checked
On this page
Key facts
- RICS's consumer guide (March 2023): a roof space that is not lived in does not need to be heated.[1]
- The Energy Saving Trust (page last updated 15 October 2025) recommends a minimum insulation depth of 270 mm for a loft.[2]
- None of the under-rafter multifoil approvals opened covers a cold loft insulated at ceiling level.[3][4][5]
- Every worked example in the three BBA approvals includes other insulation: for an existing roof, 45 to 125 mm of rigid board (U-value 0.18 W/m²K).[3][4][5]
- NHBC Standards for new homes (updated 17 October 2024): under a high-resistance underlay, a warm roof needs a ventilation path of at least 25 mm.[6]
- Bromley Trading Standards (3 February 2026) reported one household charged £8,500 for removal plus new rock wool.[7]
- A Cornwall energy charity's undated page, which carries a Cornwall Council Trading Standards warning, says adding foil to a loft is not advised.[8]
Does something need to replace the spray foam?
Not necessarily in the same place.
Is your loft a cold loft or a room in the roof?
A cold loft is a roof space that is not lived in, with the insulation at ceiling level, also called the loft floor.
Mineral wool at ceiling level: what do the sources say?
RICS's consumer guide (March 2023) prefers ceiling-level insulation where the loft is not lived in, and says topping up mineral wool is "substantially…
Multifoil under the rafters: what do the approvals cover?
Two of the approvals opened describe roofs where the ceiling follows the roof pitch and encloses a habitable space.
What about rigid board between the rafters?
The sources held say little about rigid board by itself: it appears as the extra insulation in the multifoil approvals.
What has to be right whatever is fitted?
Three things come up in the sources whatever the material: the eaves, the ventilation, and what is left behind if the foam is removed.
What have removal-and-refit jobs cost, as reported?
The only figures we hold for removal with a refit in England and Wales come from one Trading Standards alert warning residents, so they are not typical prices.
Who checks the result?
No source held for this guide names anyone who routinely checks the insulation fitted after removal.
What to do next
- Work out whether your loft is a cold loft or a room in the roof.
- Ask for any refit in writing: the material, the product name, the thickness, where it goes and how the roof will be ventilated.
- Find out which underlay your roof has before agreeing to insulation at rafter level.
- If multifoil has already gone in, see multifoil fitted after spray foam removal: what to check.
Foam removed and foil fitted? Get both checked
A Post-Removal & Insulation Check looks for remaining foam at every accessible point, records the condition of the timbers that can be reached, and checks the new insulation against its product approval.
Report within 48–72 hours of inspection. Independent: no installation, no removal, no referral commissions.
Travel included within about three hours of the North West; a fixed supplement further away, shown with your total before you book.
It's evidence for your own decisions. It records what can be seen and measured, and says what is hidden.
Questions first? Call or WhatsApp 07349 718935 WhatsApp (opens in a new tab)
Case files like this
Anonymised inspections Jan has carried out. Every loft is different.
See all case filesGo deeper: the original sources
4 original documents, each with a note on what it covers.
Questions people ask
What is the best insulation after spray foam removal?
We found no public body guidance on which insulation should follow removal, as of 10 November 2026. For a loft that is not lived in, RICS's guide (March 2023) says insulating at ceiling level is preferred.[1] The Energy Saving Trust (page last updated 15 October 2025) recommends a minimum insulation depth of 270 mm for a loft.[2] This guide reports what each source says and does not recommend a material.
Can multifoil be fitted after spray foam removal?
Two of the under-rafter approvals opened describe a roof that encloses a habitable space.[3][5] Both include other insulation in every worked example and say the space above should be ventilated under a high-resistance underlay.[3][5] None of the three addresses a cold loft, and a Cornwall energy charity's undated page, which carries a Cornwall Council Trading Standards warning, says adding foil to a loft is not advised.[3][4][5][8]
How thick should loft insulation be after spray foam removal?
For a loft, the Energy Saving Trust (page last updated 15 October 2025) recommends a minimum insulation depth of 270 mm.[2] That is the Trust's recommendation: Approved Document L for England (2021 edition, in force 15 June 2022) sets U-values, not depths.[10] At rafter level, the multifoil approvals' existing-roof worked examples add 45 to 125 mm of rigid board to reach a U-value of 0.18.[3][4][5]
How much does spray foam removal and new insulation cost?
We hold no survey of typical prices. The figures used on this page are four cases in a Bromley Trading Standards alert of 3 February 2026, including £9,000 for removal and £8,500 for removal plus new rock wool.[7] They come from a warning to residents, so treat them as reported cases and not as a guide price.
Sources
13 sources, numbered as cited in the text. Tap a footnote number to jump to its source.