It depends on the kind of loft. Two of the three under-rafter product approvals opened describe a roof that encloses a habitable space, and none addresses a cold loft or insulation at loft-floor level.[1][2][3] The Energy Saving Trust (page last updated 15 October 2025) recommends a minimum insulation depth of 270 mm for a loft.[4]
On this page
Key facts
- Two BBA approvals describe roofs where the ceiling follows the roof pitch and encloses a habitable space.[1][3]
- None of the four approvals opened addresses a cold loft or insulation at loft-floor level, and no approval for floors was opened.[1][2][3][5]
- Every worked example in the three BBA approvals includes other insulation: for an existing roof, 45 to 125 mm of rigid board (U-value 0.18 W/m²K).[1][2][3]
- The Energy Saving Trust (page last updated 15 October 2025) recommends a minimum insulation depth of 270 mm for a loft.[4]
- RICS's consumer guide (March 2023): a roof space that is not lived in does not need to be heated.[6]
- A Cornwall energy charity's undated page, which carries a Cornwall Council Trading Standards warning, says foil in a loft is not advised and gives little benefit.[7]
- Approved Document L 2026 for England (in force 24 March 2027): renovated or retained roofs, threshold U-value 0.35, improved value 0.16.[8][9]
Is foil insulation good for lofts?
It depends on whether the loft has a room in it.
Cold loft or room in the roof: why does it matter?
It matters because the insulation goes in a different place in each.
What do the product approvals cover?
Two of the under-rafter approvals opened describe roofs where the ceiling follows the roof pitch and encloses a habitable space, plus dormer cheeks (the…
What does foil under the rafters do over a cold loft?
The sources held do not measure it.
What do public bodies say?
One public warning names foil, and it reaches us through a Cornwall energy charity's undated page, quoting Cornwall Council Trading Standards, not the…
What is normally recommended for a cold loft?
Insulation at ceiling level is what the sources held describe.
Can foil insulation be used in a loft conversion?
Two of the under-rafter approvals opened describe this use: a roof where the ceiling follows the pitch and encloses a habitable space.
What are the pros and cons of foil insulation in a loft?
The sources held give conditions and warnings more than plain pros and cons, and they differ by loft type.
What to do next
- Work out whether your loft is a cold loft or has a room in it.
- If foil is offered for a cold loft, ask in writing which product approval covers that use.
- For a loft conversion, ask for the product name, the U-value calculation and the extra insulation included. See thinking of having multifoil fitted?.
- If foil is offered to replace spray foam, see what insulation should replace spray foam after removal?.
- If foil is already in your loft, an independent inspection records what can be seen and measured, and says what is hidden.
Get the foil checked independently
A Multifoil / Foil Inspection records what is fitted, how it is fixed and sealed, the air gaps and ventilation that can be seen, and moisture readings at the timbers that can be reached.
Report within 48–72 hours of inspection. Independent: no installation, no removal, no referral commissions.
Travel included within about three hours of the North West; a fixed supplement further away, shown with your total before you book.
It's evidence for your own decisions. It records what can be seen and measured, and says what is hidden.
Questions first? Call or WhatsApp 07349 718935 WhatsApp (opens in a new tab)
Go deeper: the original sources
5 original documents, each with a note on what it covers.
Questions people ask
Can I put foil insulation on the loft floor?
None of the product approvals opened covers it. They are for use at rafter level; none addresses a cold loft or insulation at loft-floor level, and no approval for use on a floor was opened.[1][2][3][5] For a loft, the Energy Saving Trust (page last updated 15 October 2025) recommends a minimum insulation depth of 270 mm.[4] Whether another foil product has an approval for floors is not known to us.
Is foil insulation better than fibreglass in a loft?
The sources held do not rank the two, and this guide does not either. For a loft, the Energy Saving Trust (page last updated 15 October 2025) recommends a minimum insulation depth of 270 mm.[4] At rafter level, every worked example in the three BBA approvals includes other insulation, so the approvals treat multifoil as one part of the roof build-up.[1][2][3]
Is it worth putting multifoil insulation in the loft?
That depends on the loft, and the sources held do not give a plain yes or no. For a cold loft, a Cornwall energy charity's undated page, which carries a Cornwall Council Trading Standards warning, says adding foil to a loft is not advised and gives little benefit there, though it says foil suits some situations.[7] For a room in the roof, two of the approvals opened describe the use, with other insulation in every worked example.[1][3]
How much does foil loft insulation cost?
We hold no typical price. The only figure we hold from a public warning is one case on a Cornwall energy charity's undated page, quoting Cornwall Council Trading Standards: the price started at £9,000, fell to £8,000 and ended at £5,900, for foil in a loft already fully insulated with mineral wool.[7] It is a reported sales case, not a guide price.
Does foil under the rafters cause condensation in a cold loft?
One source says it can. A Cornwall energy charity's undated page, which carries a Cornwall Council Trading Standards warning, says foil added to a loft can trap moisture in the rafters.[7] None of the under-rafter approvals opened covers a cold loft insulated at ceiling level.[1][2][3] We hold no test of foil in this position.
Sources