Independent · every fact sourced · reviewed by Jan Pospisil

    The UK Multifoil Guide

    The UK Multifoil Guide gives independent, sourced answers on multifoil and foil insulation in homes in England and Wales. Every fact is footnoted to its source, and the guide is reviewed weekly. Its publisher, SprayFoamCheck, is an independent inspector with nothing to sell except an inspection.

    Last reviewed 26 November 2026 by Jan Pospisil, DEA qualified (ABBE Level 3)

    Reviewed weekly: every fact checked against the news and its sources. Page last updated 26 November 2026.

    Includes time-sensitive information: checked in the weekly sweep

    Independent: SprayFoamCheck doesn't install or remove insulation and takes no referral fees.

    • 32sourced pages, from air gaps and condensation to foil fitted after spray foam removal
    • 80sources: product approvals, building regulations and public bodies, each one linked

    Start with your situation

    Not sure where to start?

    Should I worry about my foil insulation?

    Answer up to four questions to find the right page. Nothing you enter is sent anywhere.

    Step 1 of 4

    What best describes your situation?

    Questions people ask

    Is foil insulation any good?

    Laboratory tests measured less than comparison tests claimed. LABC reported in April 2008 that NPL hot-box tests gave 1.69 to 1.71 m²K/W of thermal resistance, against comparative-test claims of 5 to 6.[1] The same note says products with a product approval are acceptable when used strictly as it sets out.[1] Read more: does multifoil work?

    Read more: Read more: does multifoil work?

    Does foil insulation need an air gap?

    Yes. BRE's U-value conventions (BR 443, 2019 edition) say a foil surface adds thermal resistance only where it faces an air space, and beyond 25 mm an unventilated cavity keeps the same resistance.[2] The three BBA approvals we opened count an unventilated roof cavity from 13 mm; two count a wall cavity from 20 mm.[3][4][5] Read more: air gaps explained

    Read more: Read more: air gaps explained

    Does foil insulation cause condensation?

    It depends how it is fitted. Two BBA approvals we opened say the space under a roof underlay (felt) with a high vapour resistance should be ventilated.[3][5] A Cornwall energy charity's page, which carries a Cornwall Council Trading Standards warning (undated), says foil added to a loft can trap moisture in the rafters.[6] Read more: foil and condensation

    Read more: Read more: foil and condensation

    Is multifoil a vapour barrier or breathable?

    It depends on the type. The under-rafter multifoils whose BBA approvals we opened can act as vapour control layers (vapour barriers) when laps and joints are sealed.[3][4][5] The one breathable multifoil whose approval we opened (Kiwa, June 2021) is for use over rafters, not under them.[7] Read more: what is multifoil?

    Read more: Read more: what is multifoil?

    Does multifoil meet building regulations on its own?

    Not in the product approvals we opened: every worked example in the three BBA approvals includes other insulation.[3][4][5] One says additional insulation "will be required" to meet national thermal requirements.[3] England's 2021 Approved Document L gives 0.15 W/m²K as the U-value for a new or replacement roof element in an existing home.[8] Read more: building regulations

    Read more: Read more: building regulations

    Is multifoil really equal to 200 mm of mineral wool?

    A press report and one independent writer say the claim rests on a comparison test, not a laboratory value: 25 mm of multifoil against 200 mm of mineral wool in two chalets in France in about 1997.[9][10] The Advertising Standards Authority (ASA) upheld a complaint about it, an undated article in Building says.[9] Read more: multifoil's UK history

    Read more: Read more: multifoil's UK history

    I had spray foam removed and foil fitted: how do I know it was done properly?

    Check it against the product approval for that foil. The three BBA approvals we opened set out taped laps and battens over the foil, and their worked examples include other insulation.[3][4][5] Not every installation is a problem, and an inspection records only what can be seen and measured. Read more: after spray foam removal

    Read more: Read more: after spray foam removal

    What should replace spray foam after removal?

    If the foam is removed, we found no public body's guidance on what should replace it, as of 10 November 2026. RICS's spray foam guide (March 2023) prefers ceiling-level insulation where the loft is not lived in.[11] No under-rafter multifoil approval we opened covers a loft insulated at ceiling level.[3][4][5] Read more: replacing spray foam

    Read more: Read more: replacing spray foam

    Is my multifoil's BBA approval still valid?

    UKAS said on 15 June 2026 that existing BBA approvals remain valid until they expire.[12] UKAS suspended the BBA on 26 February 2026. The latest end date in UKAS's statement, 25 November 2026, has passed; UKAS had published no update when we checked on 26 November 2026, and the BBA's home page still said the suspension was in place.[12][13] We have not checked any approval on the BBA's register. Read more: product approvals

    Read more: Read more: product approvals

    Is foil insulation flammable?

    Multifoil can burn, according to the three BBA approvals we opened: they say their multifoils melt and shrink from heat but burn in a naked flame, and with a lining board are contained between the roof and the board.[3][4][5] All four approvals we opened say the multifoil must not touch heat sources above 80 °C.[3][4][5][7] Read more: fire safety

    Read more: Read more: fire safety

    All topics

    After spray foam removal

    Basics

    Installation and performance

    Buying and selling

    Rights and sales practices

    Reference

    For professionals

    What's changed recently

    • 26 November 2026: the latest end date UKAS gave for the BBA's suspension, 25 November 2026, has passed. UKAS had published no update when we checked on 26 November 2026, and the BBA's home page still said the suspension was in place.[12][13]
    • 20 November 2026: this guide was published. The BBA's UKAS status, suspended since 26 February 2026, was still suspended when we checked.[12]
    • 10 November 2026: the BBA's UKAS status, suspended since 26 February 2026, was still suspended.[12][13]
    • 10 September 2026: a government consultation on consumer protection for home upgrade schemes closed; no outcome published as of 10 November 2026.[14]
    • 8 September 2026: a revised copy of England's 2026 Approved Document L was published, with minor corrections.[15][16]
    • 28 August 2026: the Property Care Association (PCA), a trade body, was reported to have opened a membership branch for spray foam removal contractors.[17]

    Full change log

    How this guide is written

    How this guide is written

    Primary sources come first: official documents, standards bodies' records and product approvals, opened and read. Every fact is footnoted to its source. Anything not opened is left out or marked. Claims from other sites are checked against the original sources in claims we checked. No installer, removal firm, claims firm or law firm is named. Manufacturers are never ranked or recommended. The guide is reviewed weekly, and anything that can change is dated. It is written by Jan Pospisil of SprayFoamCheck, an independent inspector with no link to any installer or removal firm.

    The UK Spray Foam Guide

    Our sister guide is The UK Spray Foam Guide. Where the law is the same for both, this guide links to its pages. The spray foam guide also covers what to check in a loft straight after removal.

    Your next step

    Get the foil checked independently

    A Multifoil / Foil Inspection records what is fitted, how it is fixed and sealed, the air gaps and ventilation that can be seen, and moisture readings at the timbers that can be reached.

    Multifoil / Foil Insulation Inspection£295

    Report within 48–72 hours of inspection. Independent: no installation, no removal, no referral commissions.

    Travel included within about three hours of the North West; a fixed supplement further away, shown with your total before you book.

    It's evidence for your own decisions. It records what can be seen and measured, and says what is hidden.

    Questions first? Call or WhatsApp 07349 718935 WhatsApp (opens in a new tab)

    Not sure yet? Use the installation checklist

    Sources

    17 sources, numbered as cited in the text. Tap a footnote number to jump to its source.

    Call Email WhatsApp