This glossary explains the terms used in The UK Multifoil Guide, from air gap to warranty, in plain English. It covers the product, the parts of a roof, moisture, tests and standards, product approvals, fire, and buying, selling and consumer rights. Where a definition gives a figure, a date or a rule, it names its source.
On this page
About these terms
Terms are in A to Z order.
Terms A–Z
- Air gap (cavity)
- The space left beside the multifoil. BR 443 says a low-emissivity surface adds thermal resistance only when it faces an airspace; against another surface it adds nothing.[1] See: does foil insulation need an air gap?
- Approved Document L
- The government document that sets U-values, including for roofs, for building work on homes in England; Wales has its own editions. England's 2021 edition has been in force since 15 June 2022, and its 2026 edition takes effect on 24 March 2027.[2][3][4][5] See: multifoil and building regulations
- Batten
- A strip of timber. In the three BBA approvals opened, battens are fixed over the multifoil and the plasterboard is fixed to them.[6][7][8] Where battens squash a multifoil, the BBA's conventions count its thickness there as zero unless a robust figure exists.[9]
- BBA
- A body that issues product approvals; three of the multifoil approvals we opened are BBA documents.[6][7][8] UKAS suspended the BBA on 26 February 2026.[10] The latest end date UKAS gave, 25 November 2026, has passed; UKAS had published no update when we checked on 26 November 2026, and the BBA's home page still said the suspension was in place.[10][11] UKAS says existing approvals remain valid until they expire.[10] See: multifoil product approvals
- BR 443
- BRE's conventions for U-value calculations, which England's 2026 edition of Approved Document L uses for assessing U-values. The 2019 edition was published in November 2020. Its default for a multifoil with no correctly measured data is 1.7 m²K/W, airspaces included.[1][3]
- Breathable multifoil
- A multifoil made to let water vapour pass through. The one whose approval we opened is for use over the rafters, not under them; the under-rafter products opened are vapour control layers once taped.[12][6][7][8] See: what is multifoil insulation?
- BS 5250
- The British Standard that the BBA approvals opened point to on condensation, and NHBC Standards point to on roof ventilation. The current edition, BS 5250:2021, was published on 31 October 2021; the BBA approvals opened still cite the 2011 edition.[13][6][7][8][14] See: does foil insulation cause condensation?
- BS EN 16012
- A test standard for reflective insulation products. It was withdrawn on 13 July 2023 and replaced the same day by BS EN ISO 22097:2023. The BBA approvals opened, and the BBA's January 2025 conventions, still cite it.[15][16][6][7][8][9]
- BS EN ISO 22097
- The standard that replaced BS EN 16012 on 13 July 2023, the day the older standard was withdrawn.[15][16] The BBA approvals opened were issued before then and cite the older one.[6][7][8]
- Bubble foil
- Reflective foil insulation with a bubble-sheet core. The BBA's conventions treat it as a separate kind from multifoil, which has two or more foil layers with low-density wadding between them.[9]
- Building control
- The bodies that check building work against the building regulations. A government circular of 18 June 2009 says only hot-box or approved European results carry a statutory presumption, though building control bodies may still weigh other evidence.[17] See: multifoil and building regulations
- Class 0
- A national reaction-to-fire class tied to the BS 476 test series; it is not a European class. A government circular of 2 September 2024 says the national classes were removed from Approved Document B, for England, from 2 March 2025.[18][19] See: is foil insulation flammable?
- Cold loft
- A loft that is not lived in, with the insulation at ceiling level. None of the four product approvals opened addresses a cold loft or insulation at loft-floor level.[6][7][8][12] See: is foil insulation good for lofts?
- Comparative test
- A test that compares insulation in paired buildings instead of measuring it in a laboratory.[20][21] LABC's April 2008 guidance note said no national, European or international standard existed for comparative tests.[22] See: does multifoil insulation work?
- Cooling-off period
- The common name for the 14-day cancellation period for off-premises contracts. A November 2025 guide from the Chartered Trading Standards Institute (CTSI) and the Department for Business and Trade says work should not start inside it unless the consumer asks.[23] See: your rights and redress
- Core resistance
- The thermal resistance of the multifoil alone, with no air gaps counted. In the product approvals opened it runs from 0.91 to 3.58 m²K/W, depending on the product.[6][7][8][12] See: does multifoil insulation work?
- Counter-batten
- Our name for a batten fixed over the multifoil. The BBA approvals opened mostly say battens; one figure in one of them says counter-battens.[6][7][8] One approval sets them at no more than 600 mm centres.[7] Plasterboard is fixed to them.[6][7][8] See: how to check multifoil was installed properly
- De-rating (cables)
- Treating a cable as having a lower capacity than it has in free air, because insulation covers it. One BBA approval opened says covered cables may need de-rating, to as low as half their free-air capacity.[7] See: is foil insulation flammable?
- Dormer cheek
- The side of a dormer, a window that stands up out of a sloping roof. Two BBA approvals opened cover dormer cheeks and dwarf walls, as well as roofs where the ceiling follows the roof pitch.[6][8]
- Downlight
- A light fitting recessed into the ceiling. One BBA approval opened says to follow the fitting maker's guidance.[7] All three BBA approvals opened say the multifoil must not touch anything above 80 °C.[6][7][8] See: is foil insulation flammable?
- Dwarf wall
- A low wall at the edge of a loft room. Two BBA approvals opened cover dwarf walls and dormer cheeks, as well as roofs where the ceiling follows the roof pitch.[6][8]
- Eaves
- The lower edge of the roof, where the rafters meet the wall. Two BBA approvals opened say the multifoil is cut around the rafters there and sealed with tape to the wall plate.[6][7]
- Emissivity
- How readily a surface gives off radiant heat. BR 443's default airspace figures assume 0.2, and it allows a lower figure only where a product approval states one; the approvals opened state 0.03 or 0.05 for the foil.[1][6][7][8][12]
- Euroclass
- A short name for a European reaction-to-fire class. The product approvals opened give each multifoil a class of D, E or F.[6][7][8][12] The government documents we opened do not list what each letter means, so we do not explain or compare them.[18][19] See: is foil insulation flammable?
- Financial Ombudsman Service
- The ombudsman a complaint about a card or loan provider can go to, once the provider has had eight weeks without giving a final response, or has given an unsatisfactory one.[24] We found no decision that names foil or multifoil, as of 10 November 2026. See: your rights and redress
- Flue
- The pipe or passage that carries fumes from a boiler, stove or fire. Approved Document J (England) says combustible material should be at least 200 mm from a flue's inside surface, or at least 40 mm from a masonry chimney's outer surface.[25] See: is foil insulation flammable?
- Foil-faced board
- A rigid insulation board with a foil facing. It is a different product from multifoil: BR 443 covers foil-faced boards in a separate subsection from bubble foil and multi-foil.[1]
- Foil insulation
- The everyday words homeowners use when searching for multifoil. They can also mean other foil products: between them, the BBA's conventions and BR 443 treat bubble foil and foil-faced boards as separate kinds from multifoil.[9][1] See: what is multifoil insulation?
- Future Homes Standard
- The government's name for a standard for new homes. We hold only the name, so this guide does not describe what the standard asks for.
- High-resistance underlay (bitumen felt)
- A roof underlay with a high resistance to water vapour; the Building Safety Regulator's 2024 report gives bitumen felt as its example.[26] Two BBA approvals opened say the space under such an underlay should be ventilated.[6][8] See: does foil insulation cause condensation?
- Hot-box test
- A laboratory test of the product with an airspace on each side, one of the two kinds of product data BR 443 accepts for multi-foil.[1] LABC's April 2008 guidance note cites NPL hot-box results of 1.69 to 1.71 m²K/W.[22] See: does multifoil insulation work?
- In-situ test
- A test carried out in a real building, not a laboratory. BR 443 says calculated U-values are the route for Building Regulations, and that measuring a U-value in a finished building is for non-regulatory purposes.[1] See: multifoil in the UK: the test dispute
- Interstitial condensation
- Condensation inside the layers of a roof or wall, where it cannot be seen. The BBA approvals opened treat it as acceptable when the roof is designed to BS 5250 and BR 262.[6][7][8] See: does foil insulation cause condensation?
- Kiwa
- A body that issues product approvals. The Kiwa approval we opened, for a breathable multifoil used above the rafters only, was issued in June 2021 with a stated validity of three years from issue.[12] Its register status was unchecked as of 10 November 2026. See: multifoil product approvals
- LABC registered detail
- A kind of product approval from LABC for a named product. The two we opened for multifoil had stated validity that ended on 11 November 2018 and 11 November 2019, and both call for a site-specific thermal analysis.[27] See: multifoil product approvals
- Lap
- The overlap where one sheet of multifoil meets the next. The three BBA approvals opened call for laps of at least 50 mm, sealed with tape.[6][7][8] See: how to check multifoil was installed properly
- Low-emissivity surface
- A surface with a low emissivity figure, such as the foil face of a multifoil. BR 443 says it adds thermal resistance only when it faces an airspace; against another surface it adds nothing.[1] See: does foil insulation need an air gap?
- Low-resistance (breathable) underlay
- A roof underlay with a low resistance to water vapour, often called breathable. NHBC Standards for new homes (page last updated 17 October 2024) say a warm roof under one, with an air-permeable roof covering, needs no ventilation under the underlay.[14]
- Multifoil
- Insulation made of several layers of foil separated by other materials, such as wadding. The BBA's conventions describe multifoils as soft and easily compressed by battens. Government documents write it as multi-foil.[17][9] See: what is multifoil insulation?
- NHBC Standards
- Standards from NHBC for new homes. Clause 7.2.15 (page last updated 17 October 2024) says roof ventilation should follow BS 5250:2021.[14] Each BBA approval opened says its product can meet NHBC Standards (2014, 2017 or 2018 editions) when used as the approval sets out.[6][7][8]
- Off-premises contract
- A contract agreed away from the firm's premises, such as on your doorstep. A November 2025 guide from the CTSI and the Department for Business and Trade says off-premises contracts carry a 14-day cancellation period.[23] See: cold calls about foil insulation
- Part L
- Short for the part of the building regulations that Approved Document L goes with. Approved Document L sets U-values for building work on homes in England; Wales has its own editions.[2][5] See: multifoil and building regulations
- PCA
- The Property Care Association, a trade body. On 29 July 2026 it reported fake PCA identity cards and said it did not represent removal firms. In August 2026 it opened a branch of membership for contractors who specialise in removing spray foam.[28][29] See: cold calls about foil insulation
- Product approval
- Our term for a third-party document, from a body such as the BBA, Kiwa or LABC, that sets out what a named product was assessed for and how it must be fitted. The BBA says a use not in the document has not been verified.[30][31] See: multifoil product approvals
- Q-Mark
- BM TRADA's scheme for building insulation products. It accepts either the harmonised insulation standards or its own test protocol, BIP Test Protocol 001.[32] See: multifoil in the UK: the test dispute
- R-value (thermal resistance)
- How strongly a layer resists heat passing through it. It is given in m²K/W, and higher is better. It is not a U-value, which is given in W/m²K and where lower is better.[1][2]
- Rafter
- One of the sloping timbers of the roof. In two BBA approvals opened, the multifoil is stapled tight to the underside of the rafters, from ridge to eaves.[6][7]
- Reaction to fire
- The product approvals' term for a product's own fire class. The approvals opened give European classes.[6][7][8][12] National classes such as Class 0 are a different system; a government circular says they were removed from Approved Document B (England) from 2 March 2025.[18][19]
- Reflective insulation
- A general name for insulation that uses heat-reflecting foil. BR 443 covers foil-faced boards and wool, bubble foil, multi-foil and reflective membranes; the BBA's conventions split reflective foil insulation into multifoils and products with a bubble-sheet core.[1][9]
- Room-in-roof
- A lived-in room in the roof space, such as a loft conversion, with the insulation along the rafters. Two BBA approvals opened describe this kind of roof: one where the ceiling follows the roof pitch and encloses a habitable space.[6][8] See: is foil insulation good for lofts?
- Sd value
- A figure in metres that a product approval may give as a vapour measure. The approval we opened for a breathable multifoil states an Sd value of 0.029 m.[12] We hold no source explaining how to read the figure, so we do not interpret it.
- Section 75
- Section 75 of the Consumer Credit Act 1974, as the Financial Ombudsman Service describes it, lets a customer raise a claim against the bank or lender for a supplier's breach of contract or misrepresentation. It can cover some credit, including credit cards, within price limits.[24] See: your rights and redress
- Surface condensation
- Condensation on a surface on the room side, where it can be seen. The BBA approvals opened treat it as acceptable where the roof's U-value is no worse than 0.35 W/m²K at any point.[6][7][8] See: does foil insulation cause condensation?
- TA6
- The property information form used when a home is sold. The Law Society's notes on the sixth edition (position at 1 September 2025) list no question about what insulation a home has.[33] See: buying or selling a house with multifoil
- Thermal conductivity
- A figure for how readily heat passes through a material, whatever its thickness. For multifoil, the product approvals opened declare a thermal resistance for the whole product, and that is the figure this guide uses.[6][7][8][12]
- Trading Standards
- A council service that acts on complaints about traders and publishes warnings. Citizens Advice says a report to Trading Standards goes through its consumer service, not to Trading Standards directly; its helpline is 0808 223 1133.[34][35] See: cold calls about foil insulation
- U-value
- A figure for heat loss through a whole roof, wall or floor, with all its layers. It is given in W/m²K, and lower is better. Approved Document L sets U-values, not insulation depths.[2][1] See: multifoil and building regulations
- UKAS
- The body behind the BBA's suspension. UKAS suspended the BBA on 26 February 2026 and said on 15 June 2026 that existing BBA approvals remain valid until they expire.[10] The latest end date it gave, 25 November 2026, has passed; UKAS had published no update when we checked on 26 November 2026, and the BBA's home page still said the suspension was in place.[10][11] See: multifoil product approvals
- Underlay
- The felt or membrane under the tiles. Whether it has a high or a low resistance to water vapour changes what ventilation two BBA approvals opened and NHBC Standards ask for under it.[6][8][14] See: does foil insulation cause condensation?
- Unventilated cavity
- An air gap with no air flowing through it. BR 443's default figures for a low-emissivity airspace are for an unventilated cavity at least 25 mm deep.[1] One BBA approval opened calls for an unventilated cavity on each side of the multifoil.[7] See: does foil insulation need an air gap?
- Vapour control layer
- A layer that holds back water vapour. The under-rafter multifoils in the approvals opened act as one only when their laps and joints are taped.[6][7][8] See: does foil insulation cause condensation?
- Vapour resistance
- How strongly a layer resists water vapour passing through it. The three under-rafter approvals opened state 23,000 MN·s/g in one, 1,200 MN·s/g in another and a vapour resistance factor above 300,000 in the third.[6][7][8]
- Wall plate
- The timber on top of the wall at the eaves. Two BBA approvals opened say the multifoil is cut around the rafters and sealed with tape to the wall plate.[6][7]
- Warm roof
- A roof insulated along its slope: our plain wording for a term NHBC uses. NHBC Standards for new homes (page last updated 17 October 2024) say warm roofs need an air and vapour control layer on the warm side of the insulation.[14] See: does foil insulation cause condensation?
- Warranty
- A written promise from an installer or manufacturer about a product or the work. The BBA says its product approvals do not cover warranties.[30][31] The Law Society's notes say section 6 of the sixth-edition TA6 form covers warranties.[33] See: what paperwork should you have?
Get the foil checked independently
A Multifoil / Foil Inspection records what is fitted, how it is fixed and sealed, the air gaps and ventilation that can be seen, and moisture readings at the timbers that can be reached.
Report within 48–72 hours of inspection. Independent: no installation, no removal, no referral commissions.
Travel included within about three hours of the North West; a fixed supplement further away, shown with your total before you book.
It's evidence for your own decisions. It records what can be seen and measured, and says what is hidden.
Questions first? Call or WhatsApp 07349 718935 WhatsApp (opens in a new tab)
Questions people ask
What is the difference between an R-value and a U-value?
An R-value, or thermal resistance, says how strongly one layer resists heat. It is given in m²K/W, and higher is better. A U-value is a figure for heat loss through a whole roof or wall. It is given in W/m²K, and lower is better.[1][2] The two are easy to confuse: one merchant page gives a total U-value in m²K/W, which is the unit of thermal resistance.[1] Approved Document L sets U-values.[2]
What is the difference between multifoil and bubble foil?
The BBA's conventions split reflective foil insulation into two kinds. Multifoils have two or more foil layers with low-density wadding between them; they are soft, are squashed by battens and bulge between them. The other kind has a bubble-sheet core.[9] The product approvals we opened are for multifoils.[6][7][8][12] The BBA says a product or use not in an approval has not been verified.[30][31]
Is a product approval the same as meeting building regulations?
No. A product approval describes a named product and how it should be used. The BBA's webinar of June 2021 lists as a misconception the idea that a BBA-approved product automatically meets Building Regulations.[30] Every worked example in the three BBA approvals we opened includes other insulation.[6][7][8] We found no rule requiring a BBA document in the parts we read of the 2026 edition of Approved Document L for England, as of 10 November 2026.[3]
Sources