Multifoil fitted after spray foam removal is not automatically a problem, but it should be fitted as its product approval describes. Two approvals opened set out taped joints, battens over the foil, other insulation and, where the felt has a high vapour resistance, ventilation under it.[1][2] We found no public warning naming multifoil after removal, as of 10 November 2026.
Your next step:Foam removed and foil fitted? Get both checked
On this page
Key facts
- We found no Trading Standards notice, advertising (ASA) ruling or prosecution naming multifoil fitted after spray foam removal, as of 10 November 2026.
- Bromley Trading Standards reported four cases on 3 February 2026, one of £8,500 charged for removal plus new rock wool.[3]
- A Cornwall energy charity's page, quoting Cornwall Council Trading Standards (undated), says foil insulation has been sold by cold call and at the door.[4]
- None of the four product approvals opened addresses a cold loft or insulation at loft-floor level.[1][5][2][6]
- Every worked example in the three BBA product approvals opened includes other insulation as well as the multifoil.[1][5][2]
- Where the underlay has a high vapour resistance, two approvals opened say the space under it should be ventilated.[1][2]
- Once laps and joints are taped, the under-rafter multifoils in the approvals opened act as vapour control layers, not breathable ones.[1][5][2]
What does this mean for you?
If foil was fitted under your rafters after spray foam removal, and the loft is not a room, five things matter most.
Why is foil being fitted after spray foam removal?
We hold no public source that explains why, or that counts how often it happens.
What should have been checked before the foil went in?
The roof should have been checked after the foam came out and before anything new covered it.
What do the product approvals require of the foil?
The approvals opened require the multifoil to be fixed, taped, battened and lined, and describe it used with other insulation. A product approval is a third-party document, from a body such as the BBA or Kiwa, that sets the conditions for installing a product.
- Fixing: stapled tight to the underside of the rafters, from ridge to eaves.[1][5]
- Laps: overlapped by at least 50 mm and sealed with tape. Tears and cuts are taped too.[1][5][2]
- Eaves: cut around the rafters and taped to the wall plate (the timber on top of the wall).[1][5]
- Counter-battens: battens fixed over the foil.[1][5][2]
- Lining: plasterboard fixed to those battens.[1][5][2]
- Extra insulation: one BBA approval says additional insulation "will be required"; every worked example in all three includes other insulation.[1][5][2]
- Heat: no contact with anything hotter than 80 °C.[1][5][2][6]
The details differ by product, so the approval that counts is the one for the product in your roof. We read these approvals from merchant-hosted copies and have not yet checked each one's status on the issuing body's register. The full list is in how to check multifoil was installed properly.
Multifoil installation and paperwork checklist
What the product approvals we opened ask for, and the paperwork that shows it was done. Tick what you have or can see. Print or save the list to take to the installer, building control or a surveyor.
0 of 22 items ticked
If something is missing
- Ask the installer in writing, and keep the reply.
- LABC's guidance treats a multifoil as acceptable when it is used strictly as its product approval sets out, so a mismatch matters even if the paperwork looks complete.
Based on: LABC (council-hosted) (April 2008) (opens in a new tab)
- Behind plasterboard, most of this list can't be seen. An inspection records what can be seen and tested, and says what is hidden.
Read more:How to check multifoil was installed properlyWhat paperwork you should haveMultifoil product approvalsAfter removal: what good looks like
What about old felt, ventilation and the eaves?
Where the underlay (the felt or membrane under the tiles) has a high vapour resistance, two of the approvals opened say the space under it should be…
Is foil the right replacement over a cold loft?
None of the four product approvals opened addresses a cold loft, meaning an unheated one, or insulation at loft-floor level.
Does the foil match the contract?
Only your paperwork and the product in the roof can answer that, and it matters because each product approval covers named products.
What can an independent check add?
An independent check gives you a written record of what can be seen and measured in your roof, set against the conditions in the product approval.
What to do next
- Find the quote, contract and invoice, and note the exact product name on each.
- Ask the firm in writing which product approval the foil was fitted to, and what extra insulation was included.
- Find out which underlay your roof has, and how the space above the foil is ventilated.
- If something does not match, an independent inspection can record what is there.
Foam removed and foil fitted? Get both checked
A Post-Removal & Insulation Check looks for remaining foam at every accessible point, records the condition of the timbers that can be reached, and checks the new insulation against its product approval.
Report within 48–72 hours of inspection. Independent: no installation, no removal, no referral commissions.
Travel included within about three hours of the North West; a fixed supplement further away, shown with your total before you book.
It's evidence for your own decisions. It records what can be seen and measured, and says what is hidden.
Questions first? Call or WhatsApp 07349 718935 WhatsApp (opens in a new tab)
Case files like this
Anonymised inspections Jan has carried out. Every loft is different.
See all case filesGo deeper: the original sources
3 original documents, each with a note on what it covers.
Questions people ask
Is the foil fitted after spray foam removal breathable?
Only one type of multifoil is breathable. The under-rafter products whose approvals we opened are vapour control layers once their laps and joints are taped.[1][5][2] The one breathable multifoil whose approval we opened is approved for use over the rafters, not under them.[6] If your paperwork calls the foil breathable, check that against the product's own approval.
Has Trading Standards warned about multifoil after spray foam removal?
Not that we found, as of 10 November 2026. Bromley Trading Standards reported removal cases on 3 February 2026, one with new rock wool charged for in the same job.[3] A Cornwall energy charity's page, quoting Cornwall Council Trading Standards (undated), says foil insulation has been sold by cold call and at the door.[4] Neither names multifoil fitted after removal.
Does something have to replace spray foam after removal?
We found no public guidance that says what, if anything, must follow spray foam removal, as of 10 November 2026. The RICS consumer guide on spray foam (March 2023) says an unused roof void need not be heated, so insulating at ceiling level is preferred where the loft is not a living space.[8] None of the under-rafter multifoil approvals opened covers a cold loft insulated at ceiling level.[1][5][2]
Sources