    Short answer

    Not necessarily. Not every multifoil installation is a problem; what matters is how it was fitted. The three BBA approvals opened describe taped laps and battens over the foil, and every worked example in them includes other insulation; two ask for ventilation above where the underlay has a high vapour resistance.[1][2][3]

    Your next step:Get the foil checked independently

    On this page

    Key facts

    • None of the three BBA approvals opened addresses a cold loft or insulation at loft-floor level.[1][2][3]
    • The three BBA approvals opened say the multifoil can act as a vapour control layer when its laps and joints are sealed.[1][2][3]
    • Where the underlay has a high vapour resistance, two approvals opened say the space under it should be ventilated.[1][3]
    • The approvals opened say multifoil must not touch heat sources above 80 °C.[1][2][3]
    • A Cornwall energy charity's undated page, quoting Cornwall Council Trading Standards, says foil insulation has been sold through phone calls and door-to-door visits.[4]
    Should I worry about my foil insulation?

    Answer up to four questions to find the right page. Nothing you enter is sent anywhere.

    Step 1 of 4

    What best describes your situation?

    Step by step

    1. Work out what you have and where

      Multifoil has two or more foil layers with wadding between them.[5] None of the three BBA approvals opened addresses a cold loft or insulation at loft-floor level.[1][2][3] See do I have multifoil?.

    2. Find the paperwork

      Keep the contract, the product approval (the third-party document on how the product must be fitted) and any warranty. The BBA says a product or use not in its document has not been verified.[6][7] See what paperwork should you have?.

    3. Check for condensation signs

      Note any damp, drips, mould or musty smell in the loft or rooms below (our list; the sources we hold list no signs). The three BBA approvals opened say the multifoil can act as a vapour control layer, holding back water vapour, when its laps and joints are sealed.[1][2][3] See does foil insulation cause condensation?.

    4. Check heat sources

      The approvals opened say multifoil must not touch heat sources above 80 °C.[1][2][3] Approved Document J (England, amended to 2022) keeps combustible material, which we read to include multifoil, at least 200 mm from the inside of a flue or 40 mm from the outside of a masonry chimney.[8] For downlights, one approval says to follow the fitting maker's guidance.[2] See is foil insulation flammable?.

    5. Keep vents and eaves clear

      Where the underlay (the felt or membrane under the tiles) has a high vapour resistance, two approvals opened say the space under it should be ventilated.[1][3] The Energy Saving Trust says vents must not be blocked when loft-floor insulation is laid, because that can lead to damp, and eaves vents must not be covered.[9] See how to check an installation.

    6. If someone calls, do not be rushed

      A Cornwall energy charity's undated page, quoting Cornwall Council Trading Standards, says foil insulation has been sold through phone calls and door-to-door visits.[4] The Citizens Advice consumer helpline is 0808 223 1133.[10] See cold calls about foil insulation.

    7. If in doubt, get it looked at

      An independent inspection records what can be seen and measured, and says what is hidden. It is independent evidence for your own decision, not a finding that anything must be redone. See multifoil insulation problems.

    What to do next

    • Keep your paperwork together.
    • Look again if damp, drips or mould appear.
    • If something does not match the product approval, the service is the Multifoil / Foil Inspection.
    Your next step

    Get the foil checked independently

    A Multifoil / Foil Inspection records what is fitted, how it is fixed and sealed, the air gaps and ventilation that can be seen, and moisture readings at the timbers that can be reached.

    Multifoil / Foil Insulation Inspection£295

    Report within 48–72 hours of inspection. Independent: no installation, no removal, no referral commissions.

    Travel included within about three hours of the North West; a fixed supplement further away, shown with your total before you book.

    It's evidence for your own decisions. It records what can be seen and measured, and says what is hidden.

    Questions first? Call or WhatsApp 07349 718935 WhatsApp (opens in a new tab)

    Not sure yet? Use the installation checklist

    Go deeper: the original sources

    2 original documents, each with a note on what it covers.

    Questions people ask

    Does foil insulation cause condensation?

    It depends on how it is fitted and what is above it. Where the underlay has a high vapour resistance, two approvals opened say the space under it should be ventilated.[1][3] The Building Safety Regulator's February 2024 report gives bitumen felt as its example of such an underlay.[11]

    Is foil insulation flammable?

    The three BBA approvals opened say their products melt and shrink away from heat but burn in a naked flame, and that with a lining board the insulation is contained between the roof and the board.[1][2][3] They say it must not touch heat sources above 80 °C.[1][2][3]

    Should I have my multifoil taken out?

    Not every installation is a problem, and no source we hold says multifoil must come out. We hold no evidence on how it is removed or replaced, or what that costs, as of 10 November 2026. Start by comparing what is fitted with its product approval: every worked example in the three BBA approvals opened includes other insulation as well.[1][2][3]

    Sources