The UK Multifoil Guide · Installation and performance

    Is foil insulation flammable? Fire ratings, flues, cables and downlights

    Last reviewed 26 November 2026 by Jan Pospisil, DEA qualified (ABBE Level 3)

    Reviewed weekly: every fact checked against the news and its sources. Page last updated 10 November 2026.

    Includes time-sensitive information: checked in the weekly sweep

    Independent: SprayFoamCheck doesn't install or remove insulation and takes no referral fees.

    Short answer

    Multifoil can burn, according to the three BBA product approvals we opened: they say their multifoils melt and shrink away from heat but burn in a naked flame, and with a lining board are contained between the roof and the board.[1][2][3] All four approvals we opened say the multifoil must not touch heat sources above 80 °C.[1][2][3][4]

    Your next step:Get the foil checked independently

    On this page

    Key facts

    • The three BBA approvals opened say their multifoils melt and shrink away from heat but burn in a naked flame.[1][2][3]
    • The same three say that, with a lining board, the insulation is contained between the roof and the lining board.[1][2][3]
    • The approvals opened give reaction-to-fire classes of D, E or F, depending on the product.[1][2][3][4]
    • All four approvals opened say the multifoil must not be in contact with heat sources above 80 °C.[1][2][3][4]
    • Approved Document J (England, amended to 2022): combustible material at least 200 mm from a flue's inside, or 40 mm from a masonry chimney's outside.[5]
    • One approval opened says cables wholly surrounded by insulation may need de-rating, to as low as half their free-air capacity.[2]
    • On downlights, one BBA approval opened says the fitting maker's guidance must be sought.[2]
    • Class 0 is a national reaction-to-fire class. Government removed the national classes from Approved Document B with effect from 2 March 2025 (England only).[6][7]

    Is foil insulation flammable?

    It can burn, on the evidence of the three BBA product approvals we opened.

    What fire ratings do multifoils have?

    The product approvals we opened give each multifoil a reaction-to-fire class of D, E or F, depending on the product.

    Does it need to be covered?

    The approvals describe it covered.

    How close can it go to a flue or chimney?

    For England, Approved Document J (combustion appliances and fuel storage systems) says combustible material should be at least 200 mm from the inside…

    What about cables?

    One approval opened, BBA 18/5575, says cables wholly surrounded by insulation may need de-rating, to as low as half their free-air capacity, and that a…

    What about downlights?

    Of the three BBA approvals opened, one mentions downlights: BBA 18/5575 says the fitting maker's guidance must be sought.

    What does "Class 0" or "Class 1" mean on older leaflets?

    Class 0 is a national reaction-to-fire class tied to the BS 476 test series, not a European class.

    What to do next

    • Find the product name on your paperwork, and read the reaction-to-fire class in that product's approval.
    • Where it is safe and in plain view, look for multifoil touching a flue, chimney or downlight, and note what you see.
    • Ask an electrician about cables covered by insulation, and follow the fitting maker's guidance for downlights.
    • If something does not match the approval, an independent inspection can record what can be seen and measured, and say what is hidden.
    • For the checks in order, see living with multifoil: should I worry?.
    Your next step

    Get the foil checked independently

    A Multifoil / Foil Inspection records what is fitted, how it is fixed and sealed, the air gaps and ventilation that can be seen, and moisture readings at the timbers that can be reached.

    Multifoil / Foil Insulation Inspection£295

    Report within 48–72 hours of inspection. Independent: no installation, no removal, no referral commissions.

    Travel included within about three hours of the North West; a fixed supplement further away, shown with your total before you book.

    It's evidence for your own decisions. It records what can be seen and measured, and says what is hidden.

    Questions first? Call or WhatsApp 07349 718935 WhatsApp (opens in a new tab)

    Not sure yet? Use the installation checklist

    Go deeper: the original sources

    4 original documents, each with a note on what it covers.

    Questions people ask

    Is foil insulation fire resistant?

    We found no source describing multifoil as fire resistant, as of 10 November 2026. The three BBA approvals opened say their multifoils melt and shrink away from heat but burn in a naked flame.[1][2][3] One of them says multifoil is not to be carried over junctions between roofs and walls that need fire resistance.[2]

    Is foil left uncovered in my loft a fire risk?

    We found no source that answers this for a loft, as of 10 November 2026. The three BBA approvals opened say their multifoils melt and shrink away from heat but burn in a naked flame, and that a lining board keeps the insulation contained.[1][2][3] Two warn of a fire risk if the product is ignited during maintenance while unsupported.[1][2] None of the four approvals opened addresses a cold loft.[1][2][3][4] Check what your product's approval says about the lining.

    Can foil insulation touch a downlight?

    All four approvals opened say multifoil must not be in contact with heat sources above 80 °C.[1][2][3][4] One BBA approval says the fitting maker's guidance must be sought for downlights, and the other two BBA approvals do not mention them.[1][2][3] We hold no source for a clearance distance, so the fitting maker's instructions are the place to look.

    Do cables covered by foil insulation need checking?

    They may. One approval opened, BBA 18/5575, says cables wholly surrounded by insulation may need de-rating, to as low as half their free-air capacity, and that a qualified electrician should be consulted.[2] NICEIC's explanation of BS 7671 regulation 523.9, dated 20 May 2021, says a cable totally surrounded by thermal insulation for at least 0.5 m has its capacity reduced by half.[10]