The UK Multifoil Guide · Installation and performance

    Does multifoil insulation work? What the tests show

    Last reviewed 26 November 2026 by Jan Pospisil, DEA qualified (ABBE Level 3)

    Reviewed weekly: every fact checked against the news and its sources. Page last updated 10 November 2026.

    Includes time-sensitive information: checked in the weekly sweep

    Independent: SprayFoamCheck doesn't install or remove insulation and takes no referral fees.

    Short answer

    Laboratory tests show that multifoil slows heat loss, and they have measured by how much. LABC reported in April 2008 that hot-box tests by NPL gave 1.69 to 1.71 m²K/W of thermal resistance, against comparative-test claims of 5 to 6.[1] Worked examples in the BBA's January 2025 conventions combine it with other insulation.[2]

    Your next step:Get the foil checked independently

    On this page

    Key facts

    • LABC, April 2008: laboratory hot-box tests by NPL gave 1.69 to 1.71 m²K/W for multifoil, against comparative-test claims of 5 to 6.[1]
    • BR 443 (2019 edition): the default, where no correctly measured data exist, is 1.7 m²K/W for the multifoil and its adjacent air spaces together.[3]
    • Core resistance with no air gaps, in the product approvals we opened, runs from 0.91 to 3.58 m²K/W depending on the product.[4][5][6][7]
    • Every worked example in the three BBA approvals we opened includes other insulation.[4][5][6]
    • The 200 mm claim rests on a comparison of two chalets in France in about 1997, not a laboratory value. The ASA upheld a complaint.[8][9]
    • A government circular of 18 June 2009 gives a statutory presumption only to hot-box or approved European assessment results.[10]

    Does multifoil insulation work?

    Laboratory tests show that multifoil slows heat loss, and they have measured by how much; the figures are in the tables below.

    How is its performance measured?

    It is measured as thermal resistance, using data from a recognised test body.

    What do the lab tests show?

    Two of the three sources in this table report measured values below the claims set beside them.

    What do the product approvals declare?

    They declare a core thermal resistance for each product, with no air gaps.

    Is it really equal to 200 mm of mineral wool?

    That figure is a claim from comparison tests in paired buildings, not a laboratory value.

    Why do some figures on sale pages look higher?

    In the four cases we traced, because they measure something other than the core figure in the product approval.

    Does performance last?

    The one source we hold on ageing says long-term performance "may be difficult to assess and predict".

    What does the evidence add up to?

    We give no verdict of our own; the sources above report measured values and conditions of use.

    What to do next

    • Find the product name on your paperwork and read its product approval, starting with the core resistance figure.
    • If you were given an R-value or an equivalence figure, ask whether it is the core alone or includes air gaps, and which test it comes from.
    • Ask for the U-value calculation for your roof and what other insulation it counts: see multifoil and building regulations.
    • If you want independent evidence for your own decision, a Multifoil / Foil Inspection records what can be seen and measured, and says what is hidden.
    Your next step

    Get the foil checked independently

    A Multifoil / Foil Inspection records what is fitted, how it is fixed and sealed, the air gaps and ventilation that can be seen, and moisture readings at the timbers that can be reached.

    Multifoil / Foil Insulation Inspection£295

    Report within 48–72 hours of inspection. Independent: no installation, no removal, no referral commissions.

    Travel included within about three hours of the North West; a fixed supplement further away, shown with your total before you book.

    It's evidence for your own decisions. It records what can be seen and measured, and says what is hidden.

    Questions first? Call or WhatsApp 07349 718935 WhatsApp (opens in a new tab)

    Not sure yet? Use the installation checklist

    Go deeper: the original sources

    3 original documents, each with a note on what it covers.

    Questions people ask

    What is the R-value of SuperQuilt?

    The BBA product approval for SuperQuilt (17/5388, first issued 27 January 2017, amended 3 August 2017) gives a core thermal resistance of 1.35 m²K/W with no air gaps, and 0.23 m²K/W where battens squash it to 7 mm.[4] Its worked example for an existing roof reaches a U-value of 0.18 W/m²K by adding 95 mm of phenolic board.[4]

    What is the U-value of SuperFOIL insulation?

    The approval declares a thermal resistance for each product, not a U-value. BBA approval 18/5575 (2018) gives a core resistance, with no air gaps, of 1.24 m²K/W for SF19, 1.63 for SF19+, 2.57 for SF40 and 3.58 for SF60.[5] Its worked examples for an existing roof reach a U-value of 0.18 W/m²K by adding phenolic board: 100 mm with SF19, 90 mm with SF19+, 65 mm with SF40 and 45 mm with SF60.[5]

    Does foil insulation work without an air gap?

    Only in part. The core keeps its own thermal resistance, which the approvals give with no air gaps.[4][5][6][7] But the foil surface adds resistance only where it faces an air space.[3] A deeper unventilated cavity keeps the same resistance; the loss comes from a cavity that is too shallow, ventilated or missing.[3]